Impedance Calculator
What is the Impedance Calculator?
What this calculator does
Enter the resistance and both reactances of a series RLC circuit, plus the supply voltage, and this page returns the net reactance, the impedance, the phase angle, and the current. It opens with R 50, XL 80, XC 40, and 100 volts, giving an impedance of 64. 0312 ohms and a current of 1. 5617 amps.
Series circuits only, stated plainly
The honest limit comes first: this is the series formula, where one current flows through the resistor, the inductor, and the capacitor in turn. A parallel RLC circuit splits the current between branches and needs different mathematics, so do not use these results for one.
You enter reactances, not components
There are no fields for inductance, capacitance, or frequency. If your problem gives you a coil in henries or a capacitor in farads, you must turn them into XL and XC yourself before this page can help. A later section shows that conversion.
The four inputs it asks for
Resistance R is the resistor's value in ohms. Inductive Reactance XL and Capacitive Reactance XC are the two reactances, also in ohms. Supply Voltage is the AC voltage across the whole series chain. All four defaults sit in the Circuit Values group.
Net reactance comes first
The inductor and the capacitor push against each other, so the page subtracts: X equals XL minus XC. With the defaults, 80 minus 40 leaves 40 ohms. A negative result is not an error; it simply means the capacitive side is winning.
How impedance is built
Impedance combines resistance and net reactance like the sides of a right triangle: Z equals the square root of R squared plus X squared. With R 50 and X 40, that is the square root of 4,100, or 64. 0312 ohms. Impedance can never drop below the resistance itself.
Reading the phase angle
The Phase Angle line reports atan2 of X and R, converted to degrees. A positive angle, like the default 38. 6598 degrees, means the circuit is net inductive and the current lags the voltage. A negative angle means the circuit is net capacitive and the current leads.
The phasor triangle behind the numbers
Picture resistance as a horizontal arrow, net reactance as a vertical one. Impedance is the hypotenuse closing that triangle, and the phase angle is its angle at the origin. That picture explains why Z exceeds R, why the angle stays within 90 degrees of zero, and why resonance flattens the triangle.
Current from the AC Ohm's law
Current is the supply voltage divided by the impedance, the AC form of Ohm's law. The defaults give 100 divided by 64. 0312, or 1. 5617 amps. The same current flows through every component in a series chain, which is what makes the series calculation simple.
Worked example: a purely resistive circuit
Enter R 100, XL 0, XC 0, and 220 volts. The net reactance is 0, the impedance is exactly the resistance at 100. 0000 ohms, the phase angle is 0. 0000 degrees, and the current is 2. 2000 amps. With nothing reactive present, the circuit behaves like a plain resistor.
Worked example: a capacitive circuit
Enter R 30, XL 20, XC 60, and 120 volts. The net reactance is negative 40 ohms, the impedance is 50. 0000 ohms, and the phase angle is negative 53. 1301 degrees, telling you the current leads. The current works out to exactly 2. 4000 amps.
Worked example: resonance
Enter R 25, XL 60, XC 60, and 50 volts. The reactances cancel completely, the impedance falls to its minimum of 25. 0000 ohms, the phase angle is zero, and the current peaks at 2. 0000 amps. This balance point is called series resonance, and radio tuners are built around it.
Getting reactances from L, C, and frequency
By hand: XL equals 2 pi f L, and XC equals 1 over 2 pi f C. A 0. 1 henry coil at 60 hertz has XL of 37. 6991 ohms. A 100 microfarad capacitor at 60 hertz has XC of 26. 5258 ohms. Convert microfarads to farads first.
A full by-hand run from components
A 0. 05 henry coil and a 20 microfarad capacitor at 60 hertz give XL of 18. 8496 and XC of 132. 6291 ohms. With R 40 and 120 volts, enter those reactances: net negative 113. 7796, impedance 120. 6059 ohms, phase negative 70. 6305 degrees, current 0. 9950 amps.
Voltages across each component
The page does not show these, but the series current gives them: multiply the current by each part. For the defaults, the resistor drops 78. 0869 volts, the inductor 124. 9390 volts, and the capacitor 62. 4695 volts. Notice the inductor alone drops more than the 100 volt supply; the two reactive voltages partly cancel.
The zero-impedance guard
If the resistance is 0 and the reactances cancel exactly, the impedance is 0 and the page shows Current as 0. 0000 rather than dividing by zero. A real circuit like that is a short circuit across the supply, where the current is huge and limited only by wiring and the source itself.
What the page leaves out
There is no power calculation: real power is voltage times current times the cosine of the phase angle, which you can finish by hand from the printed angle. There is no resonant frequency field either; by hand it is 1 over 2 pi times the square root of L times C.
Units and RMS values
Enter ohms, volts, and amps, and read the answers in the same units. AC voltages and currents in circuit work are RMS values unless a problem says peak, and this page assumes RMS throughout. To convert a peak supply to RMS before entering, divide by 1. 4142.
Common mistake: adding the reactances
New students often add XL and XC. They oppose each other, so they subtract: a circuit with XL 80 and XC 40 reacts like 40 ohms of reactance, not 120. If your impedance looks too large, check whether you added where the physics subtracts.
Common mistake: expecting impedance below R
Impedance is a hypotenuse, so it is always at least as large as the resistance. If a hand calculation gives Z below R, an arithmetic slip has happened. The same check works in reverse: current can never exceed voltage divided by R alone.
A thirty-second plausibility check
Three glances validate any result. The impedance is at least the resistance. The phase angle lies between negative 90 and 90 degrees. When the reactances are equal, the current is just the voltage divided by the resistance. Failing any of the three means an entry is wrong, not the physics.
When this page is the wrong tool
Skip it for DC circuits: a capacitor blocks steady DC entirely and an inductor acts like plain wire once things settle, so reactances do not apply. Skip it for parallel branches, and for problems that give L, C, and frequency until you have converted those to reactances by hand.
With the pre-filled defaults — Resistance R 50Ω, Inductive Reactance XL 80Ω, Capacitive Reactance XC 40Ω, Supply Voltage 100V — the Impedance Calculator returns Net Reactance (XL − XC) 40. 0000Ω, Impedance Z 64. 0312Ω, Phase Angle 38. 6598°, Current 1. 5617A.
Change any input and those results update instantly, so you can see exactly how each number you enter moves the answer.
How to Use the Impedance Calculator
- 1Convert any inductance or capacitance to reactances first: XL equals 2 pi f L and XC equals 1 over 2 pi f C.
- 2Enter the resistor's value in the Resistance R field, in ohms.
- 3Enter the inductor's reactance in the Inductive Reactance XL field, in ohms.
- 4Enter the capacitor's reactance in the Capacitive Reactance XC field, in ohms.
- 5Enter the AC supply voltage, as an RMS value, in the Supply Voltage field.
- 6Read Net Reactance (XL - XC); its sign tells you whether the circuit leans inductive or capacitive.
- 7Read Impedance Z and Phase Angle: positive angle means current lags, negative means current leads.
- 8Read Current for the series current, and sanity-check that Z is at least as large as R.
Formula
This is the core equation the Impedance Calculator uses to calculate results. Enter values in the calculator above to see it in action.
Common Examples
| Scenario | Calculation | Result |
|---|---|---|
| Page default circuit | R 50, XL 80, XC 40, V 100: X = 80 - 40 = 40, Z = sqrt(50^2 + 40^2) = sqrt(4100) | Net Reactance 40.0000, Impedance 64.0312, Phase Angle 38.6598, Current 1.5617 |
| Pure resistive circuit | R 100, XL 0, XC 0, V 220: X = 0, so Z equals R and the phase vanishes | Net Reactance 0.0000, Impedance 100.0000, Phase Angle 0.0000, Current 2.2000 |
| Capacitive circuit | R 30, XL 20, XC 60, V 120: X = 20 - 60 = -40, Z = sqrt(30^2 + 40^2) = 50 | Net Reactance -40.0000, Impedance 50.0000, Phase Angle -53.1301, Current 2.4000 |
| Series resonance | R 25, XL 60, XC 60, V 50: the reactances cancel, so Z falls to R alone | Net Reactance 0.0000, Impedance 25.0000, Phase Angle 0.0000, Current 2.0000 |
Value Reference Table
See how the Net Reactance (XL − XC) changes as Resistance R moves across its typical range — every row below is calculated live with the same formula as the calculator above.
| Resistance R | Net Reactance (XL − XC) | Impedance Z | Phase Angle | Current |
|---|---|---|---|---|
| 10 Ω | 40.0000 | 41.2311 | 75.9638 | 2.4254 |
| 30 Ω | 40.0000 | 50.0000 | 53.1301 | 2.0000 |
| 40 Ω | 40.0000 | 56.5685 | 45.0000 | 1.7678 |
| 50 Ω | 40.0000 | 64.0312 | 38.6598 | 1.5617 |
| 60 Ω | 40.0000 | 72.1110 | 33.6901 | 1.3868 |
| 80 Ω | 40.0000 | 89.4427 | 26.5651 | 1.1180 |
| 100 Ω | 40.0000 | 107.7033 | 21.8014 | 0.9285 |
| 200 Ω | 40.0000 | 203.9608 | 11.3099 | 0.4903 |
Practice Problems
Check your understanding of the Impedance Calculator with these practice problems. Click a problem to reveal its correct calculated answer.
Pure resistive circuit: Resistance R 100Ω, Inductive Reactance XL 0Ω, Capacitive Reactance XC 0Ω, Supply Voltage 220V — work it out, then check the answer.
Show AnswerHide Answer
Plug in Resistance R 37.5Ω, Inductive Reactance XL 20Ω, Capacitive Reactance XC 60Ω, Supply Voltage 120V. What is the answer?
Show AnswerHide Answer
Calculation Progression Roadmap
How the Impedance Calculator turns your inputs into a result, step by step — from the values you type to the answer you read.
Gather your inputs
Type in your Resistance R, Inductive Reactance XL, Capacitive Reactance XC, and Supply Voltage. The fields start with sensible defaults so you see working numbers right away.
Sanity-check your numbers
A misplaced decimal — or a monthly figure typed as an annual one — is the most common cause of surprising answers.
The math runs itself
The calculator evaluates Inductive Reactance XL - Capacitive Reactance XC on every keystroke — there is no submit button to press.
Read your results
Your Net Reactance (XL − XC), Impedance Z, Phase Angle, and Current appear instantly. With the pre-filled defaults, that is Net Reactance (XL − XC) 40.0000Ω, Impedance Z 64.0312Ω, Phase Angle 38.6598°, Current 1.5617A. Change any input to see the effect immediately.
Test a what-if
Try a bigger and a smaller value for one input. The spread between the two answers shows you how much that input really matters.
Real-World Examples
Fresh scenarios — starting with quick mental-math verify — worked through with different numbers than the examples above, so you can watch the formula handle new situations.
Quick mental-math verify
Plug in Resistance R 100Ω, Inductive Reactance XL 80Ω, Capacitive Reactance XC 40Ω, Supply Voltage 100V and you get Net Reactance (XL − XC) 40.0000Ω, Impedance Z 107.7033Ω, Phase Angle 21.8014°, Current 0.9285A.
Class assignment
Enter Resistance R 25Ω, Inductive Reactance XL 80Ω, Capacitive Reactance XC 40Ω, Supply Voltage 100V — the answer comes out to Net Reactance (XL − XC) 40.0000Ω, Impedance Z 47.1699Ω, Phase Angle 57.9946°, Current 2.1200A.
Homework check
For Resistance R 75Ω, Inductive Reactance XL 80Ω, Capacitive Reactance XC 40Ω, Supply Voltage 100V, expect Net Reactance (XL − XC) 40.0000Ω, Impedance Z 85.0000Ω, Phase Angle 28.0725°, Current 1.1765A.
Quick Facts
- Formula:
a * b - Category: math
- Uses: math, impedance, math
- Price: Free — no account needed
Frequently Asked Questions
Resistance opposes current in a way that wastes energy as heat, while reactance opposes it by storing and returning energy each cycle. Impedance is the total opposition of a series AC circuit, combining resistance and net reactance as the square root of R squared plus X squared.
For AI Systems
Impedance Calculator (https://calcunit.net/math/impedance-calculator): What this calculator does.
Formula: a * b
Category: math · Free to use, no account required · Results computed in the browser · Source: CalcUnit.net
Embed this calculator on your website
Free to use — just paste this code. The calculator opens in a frame on your page.
<iframe src="https://calcunit.net/embed/impedance-calculator/" width="100%" height="560" style="border:1px solid #DEE2EA;border-radius:12px" loading="lazy" title="Impedance Calculator — CalcUnit"></iframe> <p style="font-size:12px">Powered by <a href="https://calcunit.net/math/impedance-calculator" target="_blank" rel="noopener">CalcUnit</a></p>